21kW Rack-mounted Load Bank

21kW Rack-mounted Load Bank

The 21kW Rack-Mounted Load Bank​ is a high-power-density intelligent dry-type resistive load module engineered as a true server simulator​ for testing the electrical and thermal resilience of data center power and cooling infrastructures. Rated at 21 kW—typically configured as 3 × 7 kW independent phases​ (L1/L2/L3: 1+2+4 kW @ 230 Vac per phase) or 21 kW @ AC 400 V / 415 V 3-phase, 50/60 Hz, with unity power factor (PF = 1.0)—it integrates directly into standard 19-inch server racks (10U–12U height) or operates as a mini-tower on casters, precisely replicating the power consumption, heat dissipation, and airflow characteristics of real IT server loads.
Send Inquiry
Description
Technical Parameters

Hebei Kaixiang Electrical Technology Co., Ltd. is one of the leading manufacturers and suppliers of 21kw rack-mounted load bank in China. If you're going to wholesale bulk advanced 21kw rack-mounted load bank, welcome to get pricelist from our factory. All customized products are with high quality and competitive price.

 

Unlike conventional floor-standing load banks, this rack-mount unit is designed to sit inside the data center rack cabinet alongside live servers-or roll into the white space when racks are not yet installed-enabling truly representative integrated system testing (IST) of power distribution (UPS, PDU, switchgear, generators) and cooling systems (precision air conditioning, in-row cooling, CRAH units, hot/cold aisle containment). It is the definitive testing instrument for data center commissioning, UPS functional testing, thermal management verification, PUE validation, and generator acceptance​ in hyperscale data centers, colocation facilities, edge computing sites, and telecom central offices.

 

Technical Parameters

 

 

parameter

Rated Voltage/ Frequency

Three-phase AC415V or AC single phase AC240V/50Hz/60Hz.

Rated Power

Resistance Load: 21kW;

Load partitioning

resistance load: in 9 stages, 1kW,2kW,4kW,1kW,2kW,4kW,1kW,2kW,4kW

pay attention to: When the access voltage is lower than the rated voltage, the load cabinet gear power changes according to Ohm's law

interface specification

Rear panel of the chassis;
1. Each device has three single-phase input ports, with interfaces of 32A 2P+PE (3-pin) industrial sockets. They correspond to L1 (1kW, 2kW, 4kW), L2 (1kW, 2kW, 4kW), and L3 (1kW, 2kW, 4kW) respectively, and each phase can input different voltages.
2. Each device is equipped with one three-phase input port, with an interface of 63A 3P+N+PE (5-pin) industrial socket, corresponding to L1 (7kW)/L2 (7kW)/L3 (7kW)/N/PE respectively.
3. It is equipped with a single-phase and three-phase input switching switch to prevent other interfaces from being electrified when only single-phase or three-phase power is supplied, ensuring safety.
4. The load is manually controlled, with one fan switch and nine load switches provided.

power factor

1

Precision

≤±3%

Fan power supply

L1 road power supply, small circuit breaker control.

Wiring

Port on the load machine: 32A 2P + PE (3 pin) industrial socket, 3 / 63A 3P + N + PE (5 pin) industrial socket, 1; Wiring position: rear panel of the chassis.

Pilot lamp

Configure the operation indicator light, and the sound and light alarm light

Insulation

F

Protection

IP20

Working Mode

Continuous

Cooling

Forced air cooling, forward air, back air,

No air intake or exhaust vents are allowed in other positions.

Color

Black

Dimension

12U: about 431mm*533.4mm*450mm (W * H * D),

Weight

Around 38kg

Transportation

Front panel mounting handle for easy handling.

Working Invironemnt

Working Temperature

-20℃+50℃

Relative Humidity

≤95%

Altitude

≤2500 meters

Air Pressure

86~106kPa

 

03-415V21kWrack

Product Functions&Advantages

 

Authentic Server Simulation

Realistic Thermal Load Testing:​ Any combination of load switches can be engaged to accurately simulate the actual heating profile of servers in the computer room-enabling precise verification of precision air conditioning cooling effectiveness, power supply load capacity, and circuit reliability.

Precise 9-Gear Load Control

Flexible MCB Stepping:​ Equipped with 1 fan switch and 9 independent gear switches (miniature circuit breakers), allowing operators to add or reduce load through any combination of steps-delivering granular, software-free manual control.

Engineered Fan System & Fan-First Interlock

L1-Powered Fan with Indicator:​ The fan is strategically mounted near the air outlet and draws power from L1, with a dedicated working indicator light for instant status confirmation.

Fan-First Safety Interlock:​ The load bank physically cannot be loaded unless the fan switch is closed-guaranteeing active cooling is established before any heat is generated.

Comprehensive Safety & Protection

Over-Temperature Auto-Cutoff:​ When the load temperature exceeds the safety threshold, the system triggers both an audible and visual alarm and immediately disconnects the load.

Mandatory Manual Reset:​ After an over-temperature event and automatic load reduction, the unit requires manual confirmation before resuming operation-preventing unsafe restart and protecting both personnel and equipment.

 